Electronic-Grade Gas Distillation & Purification Unit
Purity:
6N ( 99.9999% ) or Plus
Production Capacity:
50–2000 kg/h (customizable based on fab scale).
Impurity Control:
Specific impurities (e.g., CO ≤10 ppb) shall be specified separately
Technical SPEC of Electronic-Grade Gas Distillation & Purification Unit:Technical SPEC of Electronic-Grade Gas Distillation & Purification Unit:
1. System Definition and Core Functions The electronic-grade gas distillation and purification unit is an ultra-high purity gas production system integrating catalysis, adsorption, and distillation technologies, specifically designed for high-end manufacturing industries such as semiconductors, photovoltaics, and optical fibers. Its core functions include:
1.1) Impurity Removal: - Elimination of critical contaminants including metal ions (Fe, Na, etc.), particulate matter (≤0.1μm), and moisture (H₂O <0.1ppm).
1.2) Deep Separation: - Achieving gas purity of 6N (99.9999%) or higher through multi-stage distillation.
1.3) Stable Supply: - Ensuring gas purity remains uncompromised during transportation, meeting semiconductor process requirements for ppb-level (parts per billion) impurity control.
2. Core Components and Design Features 2.1) Distillation Column System: - Energy-efficient design featuring double-effect distillation or heat pump distillation - Equipped with high-efficiency structured packing materials
2.2) Pre-treatment Unit: - Adsorption beds: Molecular sieves (H₂O removal), activated carbon (hydrocarbon removal), metal catalysts (e.g., Cu for O₂ removal)
2.3) Reactor (Optional): - Integrated catalytic combustion or thermal decomposition reactors (e.g., Pt/Al₂O₃ catalyst) for synthetic gases (HBr, SiH₄)
2.4) Control System: - PLC/DCS automated control for real-time adjustment of temperature, pressure, and reflux ratio - Online analyzers: TDLAS (laser spectroscopy) for H₂O/O₂ monitoring, ICP-MS for metal impurity detection
3. Typical Process Flow (6N-grade SiCl₄ as example) 3.1) Raw Material Pre-treatment: - Industrial-grade SiCl₄ (99.9%) undergoes H₂O and HCl removal via adsorption towers
3.2) Primary Distillation (Light-Ends Column): - Operating conditions: 80°C, 0.3MPa - Low-boiling point components (e.g., SiHCl₃) removed from column top
3.3) Secondary Distillation (Heavy-Ends Column): - Operating conditions: 120°C, 0.1MPa - 6N SiCl₄ collected from column top - Heavy metals (As, Fe, etc.) concentrated in column bottom
3.4) Post-Purification: - Low-temperature adsorption (-40°C activated alumina) to further reduce H₂O to <0.05ppm - Final filtration: 0.05μm PTFE membrane filter