Electronic-Grade Gas Distillation & Purification Unit

Purity:
6N ( 99.9999% ) or Plus
Production Capacity:
50–2000 kg/h (customizable based on fab scale).
Impurity Control:
Specific impurities (e.g., CO ≤10 ppb) shall be specified separately
Technical SPEC of Electronic-Grade Gas Distillation & Purification Unit:Technical SPEC of Electronic-Grade Gas Distillation & Purification Unit:
1. System Definition and Core Functions
The electronic-grade gas distillation and purification unit is an ultra-high purity gas production system integrating catalysis, adsorption, and distillation technologies, specifically designed for high-end manufacturing industries such as semiconductors, photovoltaics, and optical fibers. Its core functions include:

1.1) Impurity Removal:
- Elimination of critical contaminants including metal ions (Fe, Na, etc.), particulate matter (≤0.1μm), and moisture (H₂O <0.1ppm).

1.2) Deep Separation:
- Achieving gas purity of 6N (99.9999%) or higher through multi-stage distillation.

1.3) Stable Supply:
- Ensuring gas purity remains uncompromised during transportation, meeting semiconductor process requirements for ppb-level (parts per billion) impurity control.

2. Core Components and Design Features
2.1) Distillation Column System:
- Energy-efficient design featuring double-effect distillation or heat pump distillation
- Equipped with high-efficiency structured packing materials

2.2) Pre-treatment Unit:
- Adsorption beds: Molecular sieves (H₂O removal), activated carbon (hydrocarbon removal), metal catalysts (e.g., Cu for O₂ removal)

2.3) Reactor (Optional):
- Integrated catalytic combustion or thermal decomposition reactors (e.g., Pt/Al₂O₃ catalyst) for synthetic gases (HBr, SiH₄)

2.4) Control System:
- PLC/DCS automated control for real-time adjustment of temperature, pressure, and reflux ratio
- Online analyzers: TDLAS (laser spectroscopy) for H₂O/O₂ monitoring, ICP-MS for metal impurity detection

3. Typical Process Flow (6N-grade SiCl₄ as example)
3.1) Raw Material Pre-treatment:
- Industrial-grade SiCl₄ (99.9%) undergoes H₂O and HCl removal via adsorption towers

3.2) Primary Distillation (Light-Ends Column):
- Operating conditions: 80°C, 0.3MPa
- Low-boiling point components (e.g., SiHCl₃) removed from column top

3.3) Secondary Distillation (Heavy-Ends Column):
- Operating conditions: 120°C, 0.1MPa
- 6N SiCl₄ collected from column top
- Heavy metals (As, Fe, etc.) concentrated in column bottom

3.4) Post-Purification:
- Low-temperature adsorption (-40°C activated alumina) to further reduce H₂O to <0.05ppm
- Final filtration: 0.05μm PTFE membrane filter

Application Fields
Photovoltaic
Chemical industry
Lithium battery
Chip industry